Gas & Refractory Blend Temperature Measurement
Gas & Refractory Blend Temperature Measurement
Customer Requirement
- IR pyrometer to be capable of continuous monitoring of high-temperature Blend (Gas+refractory) in main combustion chamber of Sulphur recovery unit in acid gas service in refinery
Systems and Tools
- Williamson SRU-4B sensor for gas temperature measurement
- All accessories like, flange mount, vortex tube, clean rod, remote display and stands to be supplied as standard
- Infrared technology avoids contact with corrosive gases
- Compact fiber-optic configuration eliminates bulk and active cooling
- Warm flange mounting reduces or eliminates sulfur deposition within the optical path
- Allows the process to be run efficiently at high temperatures
Project Scope
- Supervision of intallation and commissioning